Radon Vent Pipe Installation

One option is a liquid filled manometer 10 to 30 online mounted on the pvc pipe.
Radon vent pipe installation. Http www certi us this video is based upon the do it yourself book protecting your home from radon which thousands of homeowners have used to either reduce. The radon fan must be installed in the attic. See the guide radon fan. The safety siren radon detector for example sounds an alarm when radon levels become dangerous 130 online.
The 3 or 4 radon pipe should exit the rear roof and must have at least 24 of vertical rise in the attic in order to install the radon fan. Run a 3 inch or 4 inch solid pvc schedule 40 pipe like the ones commonly used for plumbing vertically from the gravel layer stubbed up when the slab is poured through the house s conditioned space and roof to safely vent radon and other soil gases outside above the house. Electronic monitors that measure radon in the air are another option. Once the pvc pipe is installed test the sub slab communication again to check the system.
Looking at radon mitigation systems in central new york you will see a wide range of installation methods including the location of radon vent pipes. Another important aspect of the radon piping installation is that it must vent 12 above a roof of the building not highest roof or above the peak is required also the pipe must be at least 10 feet from any windows or skylights that can be opened this can be disregarded if the pipe is 2 above the opening. Avoid routing radon pipe up through the master bedroom walls and never route the pipe into a cathedral ceiling area. Install a vertical pvc pipe running from beneath the slab and extending through an exit point above the roof line this pipe diverts the air and radon particles out of the house.
Although serving a different purpose this vent pipe. The pipe exits the attic through the roof. When it comes to radon vent pipe clearances it can be confusing what is and what s not allowed what s safe and what is not. Install an active radon vent system consisting of an in line fan installed in a vertical vent pipe extending up from a sub slab collection pipe or mat through the conditioned space of the home and through the roof that uses the fan to pull soil gases up and out of the house.
When the liquid level drops the system isn t working. Determine vent pipe size and location. Diy radon mitigation is no small feat but for those confident enough in their abilities we are providing step by step instructions to a diy radon mitigation system installation.